Posté le 15 avril 2026 / 2
Catégorie : report / Réparation-troubleshooting-works
Types d'article : réparation-dépannage instrumentiste / Défaut général
Poste technique : 240424792

Your browser cannot display the PDF.Download the PDF

Report_2026216792.pdf

INTERVENTION REPORT Nº 216792
18 Bis Avenue de Bruxelles
13127 VITROLLES
04 84 34 13 13
CUSTOMER DATE: CONTRACT N° / TYPE
04/15/2026 ARCELOR MITTAL / CC 10T CC2ARCELOR MITTAL DEVICE NAME: DEVICE NUMBER / TYPE
00002762
MINIMUM CARGO LIFT
23AM2762
CUSTOMER APP Nº: INSTALLATION ADDRESS: ZI AILE 22 / FOS SUR MER CEDEX LOCATION: CC 10T CC2 INTERVENTION REQUEST Contact: : Arcelor
Date/Time Call: Telephone: 04/15/2026 11:00 DETAILS OF THE INTERVENTION
Broken-down
Origin: Location: :
Equipment:
State:
Action:
Fence:
Technical failure
Vantaux
USE
Replacement of parts
Return to service
Arrived on site, landing door at 0m, opens crooked - Check the synchronization brackets, 2 blocks are out of order - Replace the blocks then carry out tests - OK - Plan to replace the synchronization gears
Pattern:
Resolution:
Comments:
DATE
START TIME
TIME END 04/15/2026 11:00 12:30
REPLACED MATERIALQX
000053Customer unavailableName: PHOTOS
PEREIRA SERRANO LUIS
TECHNICIAN SIGNATURE
CUSTOMER SIGNATURE: Technician: DEVICE STOPPED NoYes

PointFinder type:Repair – Troubleshooting – Work

Caractéristiques
Event Details
Start Date:
15/04/2026
End Date:
15/04/2026
Start Time:
11:00
End Time:
12:30
Notes et commentaires
Il n’y a pas encore de note ni commentaire
Donner une note
Vous devez être pour noter et commenter