Posté le 18 mars 2026 / 8
Catégorie : report / Réparation-troubleshooting-works
Types d'article : réparation-dépannage instrumentiste / Défaut général
Poste technique : 240424891

Your browser cannot display the PDF.Download the PDF

Report_2026209600.pdf

INTERVENTION REPORT Nº 209600
18 Bis Avenue de Bruxelles
13127 VITROLLES
04 84 34 13 13
CUSTOMER DATE: CONTRACT N° / TYPE
03/17/2026 ARCELOR MITTAL / 2T ACIERIEARCELOR MITTAL DEVICE NAME: DEVICE NUMBER / TYPE
00002758
MINIMUM CARGO LIFT
23AM2758
CUSTOMER APP Nº: INSTALLATION ADDRESS: ZI AILE 22 / FOS SUR MER CEDEX LOCATION: 2T STEEL PLANT REQUEST FOR INTERVENTION Contact: : Arcelor
Date/Time Call: Telephone: 03/17/2026 5:50 p.m. DETAILS OF THE INTERVENTION
Broken-down
Origin: Location: :
Equipment:
State:
Action:
Fence:
Technical failure
electric lock
ENCRASSE
DIAGNOSIS TO BE FURTHER DEEP (NOT FOUND)
Indisponible
When I arrived, device between floors -> Assembled in the machinery for a diagnosis -> Arrived in the safety chain machinery - OK but device faulty -> Anti-skid -> Acknowledged the fault then restarted -> Device which starts then cuts off during its cycle -> Check of the 11m lock, dirty lock, need for a new intervention to dismantle the lock -> Device shut down
Pattern:
Resolution:
Comments:
DATE
START TIME
TIME END 03/17/2026 5:50 p.m. 6:30 p.m.
REPLACED MATERIALQX 000053Customer unavailableName: PHOTOS
PEREIRA SERRANO LUIS
TECHNICIAN SIGNATURE
CUSTOMER SIGNATURE: Technician: DEVICE STOPPED NoYes

PointFinder type:Repair – Troubleshooting – Work

Caractéristiques
Event Details
Start Date:
17/03/2026
End Date:
17/03/2026
Start Time:
17:50
End Time:
18:30
Notes et commentaires
Il n’y a pas encore de note ni commentaire
Donner une note
Vous devez être pour noter et commenter