MAINTENANCE REPORT Nº 205620
13127 VITROLLES
18 Bis Avenue de Bruxelles
04 84 34 13 13
CUSTOMER DATE: DEVICE NAME: DEVICE NUMBER / TYPE
Nº / TYPE CONTRACT
02/03/2026 ARCELOR MITTAL ARCELOR MITTAL / PDC PCB3 23AM2781
MINIMAL
00002781
MONTE-CHARGE
CUSTOMER APP N°: INSTALLATION ADDRESS: LOCATION: ZI AILE 22 / FOS SUR MER CEDEX PDC PCB3
Machinery access control (red key box, ladder, room closure, lighting, etc.)
Controlled Items: Revised Correct
Button and display control (fct, illuminated) R R
Landing door and cabin control (locking and closing contacts) R R
Precision stop and leveling control R R
Reopening device check (shock, cell, BP, etc.) R R
Cabin check (ground condition, trim, babbit, etc.) R R
Duct lighting control R R
Date: Time Start 8:30
End Time 11:0002/03/2026
Verification Phone: Test Phone: Observations Phone: OBSERVATIONS
maintenance visit door checks lubrication of guides test EQUIPMENT REPLACES QX
Name: PICTURES
TECHNICIAN SIGNATURE
CUSTOMER SIGNATURE: Technician: Road: Customer: unavailable ABDOU SOULAIMANA
0029
DEVICE STOPPED
OuiNon
PointFinder type:Repair – Troubleshooting – Work