Posté le 6 novembre 2024 / 22
Catégorie : report / Réparation-troubleshooting-works
Secteur : Métallurgie - Sidérurgie

MAINTENANCE REPORT Nº101514

13127 VITROLLES

18 Bis Avenue de Bruxelles

04 84 34 13 13

CUSTOMER DATE DEVICE NUMBER / TYPE DEVICE NO. / TYPE CONTRACT

05/11/2024 ARCELOR MITTAL ARCELOR MITTAL / PDC PCB1 23AM2780

MINIMAL

00002780

CUSTOMER APP N° ADDRESS INSTALLATION LOCATION

ZI AILE 22 / FOS SUR MER CEDEX PDC PCB1

Machinery access control (red key box, ladder, room closure, lighting, etc.)

Controlled Items: Revised Correct

Button and display control (fct, illuminated) R R

Landing door and cabin control (locking and closing contacts) R R

Precision stop and leveling control R R

Reopening device check (shock, cell, BP, etc.) R R

Cabin check (ground condition, trim, babbit, etc.) R R

Duct lighting control R R

Landing door control (travel, guidance, play, cable, chain or belt, emergency release) lubrication R R

Cabin door control (travel, guidance, play, cable, chain or belt, emergency release) lubrication R R

Date: 05/11/2024 Time Start 1:51 p.m. End Time 2:30 p.m.

Phone Verification:

Phone Test:

Observations Telephone:

OBSERVATIONS

door controls lubrication of guides

MATERIAL REPLACES QX

Caractéristiques
Notes et commentaires
Il n’y a pas encore de note ni commentaire
Donner une note
Vous devez être pour noter et commenter