INTERVENTION REPORT Nº191169
18 Bis Avenue de Bruxelles
13127 VITROLLES
04 84 34 13 13
CUSTOMER DATE: CONTRACT N° / TYPE
01/02/2026 ARCELOR MITTAL / HFX HF2ARCELOR MITTAL DEVICE NAME: DEVICE N° / TYPE
00002776
MINIMUM CARGO LIFT
23AM2776
CUSTOMER APP Nº: INSTALLATION ADDRESS: ZI AILE 22 / FOS SUR MER CEDEX LOCATION: HFX HF2 INTERVENTION REQUEST Contact: :
Date/Time Call: Telephone: 02/01/2026 03:48 DETAILS OF THE INTERVENTION
broken down at 11m
Origin: Location: :
Equipment:
State:
Action:
Fence:
Technical failure
Serrure
DESSERRE
REGLAGE
Return to service
device at 11m door close
arrived on site Travel up to 11m
checking the opening (VF off, no opening)
fuse out of order checking the chains OK
closure check (no closure)
manual closing and opening recommended fuse change request
Pattern:
Resolution:
Comments:
DATE
START TIME
TIME END02/01/2026 3:48 5:21
REPLACED MATERIALQX 000059Customer unavailableName: PHOTOS
MERCIER GABRIEL
TECHNICIAN SIGNATURE
CUSTOMER SIGNATURE: Technician: DEVICE STOPPED NoYes
PointFinder type:Repair – Troubleshooting – Work