Posté le 26 august 2024 / 9
Catégorie : report / Réparation-troubleshooting-works
Secteur : Métallurgie - Sidérurgie

INTERVENTION REPORT Nº089385
18 Bis Avenue de Bruxelles
13127 VITROLLES
04 84 34 13 13
CUSTOMER DATE Nº / CONTRACT TYPE
08/23/2024 ARCELOR MITTAL ARCELOR MITTAL / SUBLANCE
DEVICE NAME / DEVICE TYPE
00002761
MINIMUM ELEVATOR
23AM2761
CUSTOMER APP NO. INSTALLATION ADDRESS
ZI AILE 22 / FOS SUR MER CEDEX
LOCALISATION
SUBLANCE
REQUEST FOR INTERVENTION
Date/Time Call: 08/22/2024 09:10 Contact: GIP Telephone: 04 42 47 36 88
DETAIL OF THE INTERVENTION
elevator broken. UB: YES / Floor: between 18 and 24 meters / Access: free / Details: people are blocked but
the gip will take them out
Origin:
Location:
Equipment:
State:
Action:
Fence:
Misuse
Cabin door contact
DEREGLE
REGLAGE
Return to service
device broken down cabin door force preliminary cabin contact out of adjustment
service reset setting
Pattern:
Resolution: Observations:
DATE 08/23/2024 START TIME 9:12 END TIME 10:31
QX REPLACED MATERIAL
Name: Customer unavailable 000025
PHOTOS
ABDOU SOULAIMANA
CUSTOMER SIGNATURE TECHNICIAN SIGNATURE
Technician:
DEVICE OFF Yes No

Caractéristiques
Notes et commentaires
Il n’y a pas encore de note ni commentaire
Donner une note
Vous devez être pour noter et commenter