Restoration of the elevator Engine replacement Cam replacement Electrocam repair Temporary lock repair 18m Temporary operation with step of 1cm at 11,18 and 24m Attention ⚠️ step of…
Voir la publication
Aucune photo
Electro cam
After cleaning the electro cam we made the heads which were not conclusive dismantling of the 18m locks for expertise
Voir la publication
Aucune photo
Parachute maintenance
Veritas control Elevator stopped following inspection Traction cables to replace and see traction pulley Parachute ok
Voir la publication
Aucune photo
Troubleshooting 22/11
And blockage at the lock 24 m due to dust entering the mechanical system
Voir la publication
Aucune photo
SUBLANCE. Door repair 18m
18 meter door repair recovery door trolley fixing conclusive test
Voir la publication
Aucune photo
Troubleshooting
Elevator repair replacement of the 11m level landing button -18 m door condemns broken striker -fixing the striker impossible to lock it, the inserts must be replaced
Voir la publication
Aucune photo
SUBLANCE Troubleshooting
Works on arrival checking the doors cabin door check test for proper operation
Voir la publication
Aucune photo
Aucune photo
Troubleshooting
Elevator to highest level current cut ero maneuver only problem observed is opening and closing the doors cleaning door thresholds conclusive test
Voir la publication
Aucune photo
Sublance troubleshooting on 09/14
Elevator blocked, door open at 11m cleaning the striker and rail at 11m 11m lock adjustment test and positive result
Voir la publication
Aucune photo
Aucune photo
Sublance Troubleshooting
Hard mechanics of a different flood. Cleaning, restoration. Locks should be replaced to stop breakdowns
Voir la publication
Aucune photo
Aucune photo
Aucune photo
SUBLANCE elevator broken down on 02/12 at 8 a.m.
GIP call: device broken: door does not open (?cabin user) Intervention: - observation: operator pulley slips (motor mounting and damaged) -adjustment of the door motor on the cabin…
Voir la publication
Aucune photo
Troubleshooting 29/11
Troubleshooting 11/29.Observation: landing door thresholds on all floors obstructed dust and water = paste